CANB_W - Accessible Internal Registers (Detailed)

Frozen Content

The following sections detail the internal CAN registers that can be accessed from the host processor.

Mode Register (MOD)

Address in CAN memory – 00h

Register value after hardware reset – 00000001

Register value after software reset or when in Bus-Off state – 0000xxx1.

Table 1. Mode register.
Bit
Name
Function

MOD.7 – MOD.5

-

Not used (when read – 000)

MOD.4

Sleep Mode

0 – Sleep Mode disabled
1 – Sleep Mode enabled. Power consumption reduced.

MOD.3

Acceptance Filter Mode

0 – dual filter mode
1 – single filter mode

MOD.2

Self Test Mode

0 – Self Test Mode disabled
1 – Self Test Mode enabled (no acknowledgement is required).

MOD.1

Listen Only Mode

0 – Listen Only Mode disabled
1 – Listen Only Mode enabled. CAN Controller has no influence on the CAN-bus (no acknowledgements, no error/overload frames sent and no message transmission is possible).

MOD.0

Reset Mode

0 – Reset Mode disabled
1 – Reset Mode enabled. This bit of the register is set when either a software or hardware reset has been issued, or when the bus-off state has been entered (SR.7 set).

MOD.1, MOD.2, MOD.3 – write access possible only in Reset Mode.

MOD.4 – write access possible only in Operating Mode.

MOD.0 – write access possible both in Reset Mode and Operating Mode.

Sleep Mode

The Controller will enter sleep mode if the following conditions are met:

  • the Sleep Mode bit (MOD.4) is set
  • there is no bus activity
  • there is no interrupt pending.

After entering Sleep Mode, the CLK_I signal is stopped and the CLK_OUT signal continues until 15 bit times have passed. This allows a host processor clocked via this signal to enter its own standby mode before the CLK_OUT goes inactive.

The Controller will wake up when one of the following conditions occurs:

  • there is bus activity
  • pin INTI is driven High (active).

On wake-up, CLK_I is started and a wake-up interrupt is generated, if enabled. If the CAN Controller wakes up due to bus activity, it enters into the BUS-OFF state. In this state, it will not be able to receive any message (including the message that caused the Controller to wake up), until it detects 11 consecutive recessive bits (bus-free sequence).


Figure 1. Sleep Mode.

Self Test Mode

For proper message transmission, no acknowledge signal is required from the CAN-bus. This mode can be used to test the CAN Controller while there is only one node connected to the Can-bus.

Listen Only Mode

During this mode of operation, the CAN Controller is disconnected from the bus.

Message transmission and message acknowledgements are not possible. This mode of operation also forces the CAN controller to be Error Passive. The Listen Only mode can be used for Can-bus monitoring (e.g. software-driven bit rate detection and 'hot plugging').

Reset Mode

This mode of operation is used for configuring the CAN Controller registers. Detection of a set Reset Mode bit (MOD.0) results in aborting the current transmission/reception of a message and entering the reset mode. On the '1-to-0' transition of the Reset Mode bit, the CAN Controller returns to the mode defined within the Mode register.

During a hardware reset (RST_I) or when the bus status bit is set to logic 1 (Bus-Off), the Reset Mode bit is also set to logic 1.

During a hardware reset, the CPU cannot set the Reset Mode bit to logic 0.

After the Reset Mode bit is set to logic 0, the CAN Controller will wait for:

  • One occurrence of bus-free signal (11 consecutive receive bits), if the preceding reset was caused by a hardware reset or a CPU-initiated reset.
  • 128 occurrences of the bus-free signal, if the preceding reset was caused by a CAN Controller-initiated Bus-Off, before re-entering the bus-on mode.

Command Register (CMR)

Address in CAN memory – 01h

This register is Write-only.

Register value returned when read – 0000000

Register value after a reset – 0000000.

Table 2.Command register.
Bit
Name
Function

CMR.7 – CMR.5

-

Reserved

CMR.4

Self Reception Request

1 – Message shall be transmitted and received simultaneously

CMR.3

Clear Data Overrun

1 – Clear Data Overrun Status bit (SR.1)

CMR.2

Release Receive Buffer

1 – Completion of reading Receive Buffer indication. Should be set after reading of a received message from the Receive FIFO has completed

CMR.1

Abort Transmission

1 – Cancel pending transmission

CMR.0

Transmission Request

1 – Message placed in Transmit Buffer shall be transmitted. Should be set after a message has been written into the Transmit Buffer.

Various combinations of bits can be set simultaneously in the Command register, initiating the following actions that have to be performed by the CAN Controller:

  • Setting CMR.0 and CMR.1 simultaneously results in Single-Shot Transmission.
  • Setting CMR.4 and CMR.1 simultaneously results in Single-Shot Transmission and simultaneous reception. No re-transmission will be performed in the event of an error or arbitration lost.
  • Setting CMR.0 and CMR.4 simultaneously will result in self reception transmission (same action as if setting CMR.4 on its own).

The Transmission Request bit (CMR.0) is cleared automatically either at the moment the Transmit Status bit (SR.5) is set (normal transmission) – signifying successful transmission of a message is in progress – or when the whole message has been read from the Transmit Buffer register by the Transmitter Unit (Single Shot Transmission).

After reading the contents of the Receive Buffer, the CPU can release this memory space in the Receive FIFO (RXFIFO) by setting the Release Receive Buffer bit (CMR.2) to logic 1. This may result in another message becoming immediately available within the Receive Buffer.

The Abort Transmission bit (CMR.1) is used to suspend the previously requested transmission (for example, when you wish to transmit a more urgent message). A transmission already in progress is not stopped.

In order to see whether the previous message has been either transmitted successfully or aborted, the Transmission Complete status bit (SR.3) should be checked. This should be done after the Transmit Buffer Status bit (SR.2) has been set to logic 1 or a transmit interrupt has been generated.

It should be noted that a transmit interrupt is generated even if the message was aborted because the Transmit Buffer Status bit changes to 'released'.

Status Register (SR)

Address in CAN memory – 02h

This register is Read-only.

Register value after hardware reset – 00111100

Register value after software reset or in Bus-Off state – xx11x100.

Table 3. Status register.
Bit
Name
Function

SR.7

Bus Status

Bus-Off state indication.

1 – Bus-Off state entered

Set when Transmit Error Counter exceeds the limit of 255. Simultaneously, the Reset Mode bit (MOD.0) is set and an Error Warning Interrupt is generated, if enabled.

SR.6

Error Status

1 – at least one of the Error Counters has reached or exceeded an Error Warning Limit

SR.5

Transmit Status

CAN Transmitter operation.

1 – CAN is transmitting a message.

SR.4

Receive Status

CAN Receiver operation.

1 – CAN is receiving a message.

SR.3

Transmission Complete

1 – Last requested transmission has been successfully completed.
Reset automatically whenever Transmission Request bit (CMR.0) or Self Reception Request bit (CMR.4) is set.

SR.2

Transmit Buffer Status

1 – CPU may write a new message into the Transmit Buffer.

SR.1

Data Overrun Status

Data overrun in Receive FIFO indication.

1 – Message has been lost. Set upon data overrun occurrence. Cleared by receiving the Clear Data Overrun command (CMR.3).

SR.0

Receive Buffer Status

1 – There is at least one message available in the Receive FIFO.

If the CPU tries to write to the Transmit Buffer when the Transmit Buffer Status bit is '0', then the written data will not be accepted and will be lost without any indication.

When a successfully received message passes through the Acceptance Filter but there is not enough space to store the message, then the message is dropped and the data overrun condition is indicated.

In Bus-Off state, when bit SR.7 is set, the Controller enters Reset Mode, the Transmit Error Counter is set to 127 and the Receive Error Counter is cleared. The Controller stays in this mode until the CPU clears the Reset Mode bit (MOD.0). The Controller then waits for 128 occurrences of the bus-free signal counting down the Transmit Error Counter. Only after the Bus Status bit (SR.7) is cleared are the error counters cleared also and an Error Warning Interrupt is generated once again (if enabled).

Errors detected during reception or transmission will effect the error counters according to the CAN 2.0B protocol specification.


Figure 2. Error states.

The CAN Controller can be in one of three error states:

  • Error Active – the normal operating state. Messages can be received and transmitted. On detecting an error an active error flag is sent.
  • Error Passive – a state entered when the Controller has frequent problems transmitting or receiving messages. Messages can be received and transmitted. On detecting an error while receiving, a passive error flag is sent.
  • Bus-Off – entered if the Controller has serious problems with transmitting messages. No messages can be received or transmitted until the CAN Controller is reset by the host microcontroller or processor.

The state of the Controller is controlled by two error counters – the Transmit Error Counter (TEC) and the Receive Error Counter (REC). The following rules apply:

  • The CAN Controller is in the Error Active state if TEC <= 127 and REC <= 127
  • The Error Passive state is entered if (TEC > 127 or REC > 127) and TEC <= 255
  • The Bus-Off state is entered if TEC > 255.

Once the CAN Controller has entered Bus-Off state, it must be reset by the CPU in order to be able to continue operation. In addition, this is only allowed after the reception of 128 occurrences of 11 consecutive recessive bits.

The counters are updated as follows:

  1. When a receiver detects an error, the REC will be incremented by 1, except when the detected error was a bit error during the sending of an active error flag or an overload flag.
     
  2. If a receiver detects a bit error while sending an active error flag or an overload flag, the REC is incremented by 8.
     
  3. When a receiver detects a dominant bit as the first bit after sending an error flag, the REC will be incremented by 8.
     
  4. When a transmitter sends an error flag, the TEC is incremented by 8, with the following exceptions:
     
    • If the transmitter is in the Error Passive state and detects an ack error (due to not detecting a dominant ack) and does not detect a dominant bit while sending its passive error flag.
    • If the transmitter sends an error flag because a stuff error occurred during arbitration – whereby the stuff bit is located before the RTR bit, should have been recessive and has been sent as recessive but monitored as dominant.
       
  5. If a transmitter detects a bit error while sending an active error flag or an overload flag, the TEC is increased by 8.
     
  6. Any node accepts up to 7 consecutive dominant bits after sending an active or passive error flag or an overload flag. After detecting the 14th consecutive dominant bit (in the case of an active error flag or an overload flag), or the 8th consecutive dominant bit following a passive error flag, and after each sequence of additional 8 consecutive dominant bits, every transmitter increases its TEC by 8 and every receiver increases its REC by 8.
     
  7. After the successful transmission of a message (getting acknowledge and no error until end of frame is finished), the TEC is decreased by 1 unless it was already 0.
     
  8. After the successful reception of a message (reception without error up to the AckSlot and the successful sending of the acknowledge bit), the REC is decreased by 1 unless it was already 0.


If a node is the only one on the bus (or during startup the only one that has become active), and it transmits a message, it will get an acknowledgement error and will retransmit the message. This may lead to that node entering the Error Passive state, but not to it entering the Bus-Off state (due to exception 1 under point 4).

Interrupt Register (IR))

Address in CAN memory – 03h

This register is Read-only.

Register value after hardware reset – 00000000

Register value after software reset or in Bus-Off state – 00000x00

Table 4. Interrupt register.
Bit
Name
Function

IR.7

Bus Error Interrupt

1 – Error on the CAN-bus.
Bit, stuff, crc, acknowledge or form error detected.

IR.6

Arbitration Lost Interrupt

1 – CAN Controller lost arbitration and becomes a receiver. Bit position where arbitration has been lost is located within Arbitration Lost Capture register.

IR.5

Error Passive Interrupt

1 – CAN Controller has reached the Error Passive state (at least one Error Counter exceeds 127) or CAN Controller changes error status from Error Passive to Error Active.

IR.4

Wake-Up Interrupt

1 – whilst sleeping, the Controller has detected either CAN-bus activity or an interrupt on the INTI input pin.

IR.3

Data Overrun Interrupt

1 – Data Overrun Status bit (SR.1) is active.

IR.2

Error Warning Interrupt

1 – Change in either the Error Status (SR.6) or Bus Status (SR.7) bits.

IR.1

Transmit Interrupt

1 – The Transmit Buffer Status bit (SR.2) has changed from '0' to '1' (released).

IR.0

Receive Interrupt

1 – Receive FIFO not empty.

The Interrupt register allows the identification of an interrupt source.

Activity of each bit depends on the state of the corresponding bit in the Interrupt Enable register. When one or more bits of the Interrupt register are set, an output interrupt will be indicated to the CPU. After this register is read by the CPU all bits are cleared except for the Receive Interrupt bit.

Giving the command to 'Release Receive Buffer' (CMR.2) will clear the Receive Interrupt bit temporarily. If there is another message available within the Receive FIFO after the release command, the Receive Interrupt bit is set again. Otherwise it remains cleared.

In the case of a Bus Error Interrupt (when a bus error occurs), the corresponding bus error interrupt is forced, if enabled. At the same time, the current position of the Bit Stream is captured into the Error Code Capture register. The content within this register is fixed until the user's software has read out its content once. The capture mechanism is then activated again. The corresponding interrupt flag is cleared during the read access to the Interrupt register. A new bus error interrupt is not possible until the capture register is read out once.

Interrupt Enable Register (IER)

Address in CAN memory – 04h

Register value after hardware reset – 00000000

Table 5. Interrupt Enable register.
Bit
Name
Function
IER.7 Bus Error Interrupt Enable Enable corresponding interrupt bit in Interrupt register.
IER.6 Arbitration Lost Interrupt Enable
IER.5 Error Passive Interrupt Enable
IER.4 Wake-Up Interrupt Enable
IER.3 Data Overrun Interrupt Enable
IER.2 Error Warning Interrupt Enable
IER.1 Transmit Interrupt Enable
IER.0 Receive Interrupt Enable

Bus Timing Registers (BTR0, BTR1)

Addresses in CAN memory – 06h (BTR0), 07h (BTR1)

These registers are Read/Write.

Register values after hardware reset – BTR0 : 00h, BTR1 : 14h

In CAN, the Nominal Bit Time, t Bit , is divided into four non-overlapping segments t Sync_Seg , t Prop_Seg , t TSeg1 and t TSeg2. In the CAN Controller, the segments t Prop_Seg and t TSeg1 are treated as one segment – t TSeg1. This facilitates the programming of bit timing parameters. The only impact of this is that t Prop_Seg must be considered while calculating parameters, before the Bit Timing Parameters are programmed.

Mathematically, the time duration of the Nominal Bit Time, t Bit , is now simply the sum of the individual segments' durations:
 
t Bit = t Sync_Seg + t TSeg1 + t TSeg2 = 1 + t TSeg1 + t TSeg2
 

Figure 3. Bus Timing.

BTR0.7
BTR0.6
BTR0.5
BTR0.4
BTR0.3
BTR0.2
BTR0.1
BTR0.0
SJW.1
SJW.0
BRP.5
BRP.4
BRP.3
BRP.2
BRP.1
BRP.0

tq – time period of the quantum clock

BRP – Bit Rate Prescaler. The system clock (CLK_I) is divided by BRP to determine the quantum clock

SJW – Synchronization Jump Width. Defines the maximum number of time quanta a bit period may be shortened or lengthened by one re-synchronization, to compensate for phase shifts between clock oscillators of different bus controllers and propagation delays between CAN-bus nodes.


BTR1.7
BTR1.6
BTR1.5
BTR1.4
BTR1.3
BTR1.2
BTR1.1
BTR1.0
SAM
TSeg2.2
TSeg2.1
TSeg2.0
TSeg1.3
TSeg1.2
TSeg1.1
TSeg1.0

TSeg1 and TSeg2 determine the number of time quanta per bit period and the location of the sample point, where:

SAM – Sampling Mode

  • 0 – Single sampling
  • 1 – Triple sampling

The CAN in Automation (CiA) International Users and Manufacturers Group has recommended some baud rates to be used in general purpose CAN networks as well as the maximum bus length for a given baud rate. In addition, the bit-timing is recommended, so that nodes from different manufacturers can be connected to one CAN network without calculating the bit-timing parameters.

Table 6. Bus timing.
Bit Rate
(Bus Length)
Nom. Bit Time (us)
Time Quanta per Bit tq/bit
Length of Time Quantum (us)
Location of Sample Point (tq)
Tseg1 (tq)
Tseg2 (tq)
BTR0 at
CLK_I = 16MHz
BTR1 at
CLK_I = 16MHz
1Mb/s (25m)
1
8
0.125
6
5
2
00h
14h
0.8Mb/s (50m)
1.25
10
0.125
8
7
2
00h
16h
0.5Mb/s (100m)
2
16
0.125
14
13
2
00h
1Ch
250kb/s (250m)
4
16
0.25
14
13
2
01h
1Ch
125kb/s (500m)
8
16
0.5
14
13
2
03h
1Ch
50kb/s (1km)
20
16
1.25
14
13
2
09h
1Ch
20kb/s (2.5km)
50
16
3.125
14
13
2
18h
1Ch
10kb/s (5km)
100
16
6.25
14
13
2
31h
1Ch

Output Control Register (OCR)

Address in CAN memory – 08h

This register is Read/Write

Register value after hardware reset – 00000010

The Output Control register allows the set-up of different output driver configurations under software control.

OCR.7
OCR.6
OCR.5
OCR.4
OCR.3
OCR.2
OCR.1
OCR.0
Octrl.5
Octrl.4
Octrl.3
Octrl.2
Octrl.1
Octrl.0
OMODE.1
OMODE.0

OCtrl.5 - OCtrl.0 – six bits reflecting the output port OUTCTRL. This port can be used for additional configuration and control of the analog output circuits or the transceiver.

OMODE – Output Mode

  • 00 – bi-phase output mode
  • 01 – test output mode
  • 10 – normal output mode
  • 11 – clock output mode.

Bi-phase Output Mode

In contrast to the normal output mode, the bit representation in the bi-phase output mode is time variant and toggled. During recessive bits, all outputs are deactivated (floating) (this is done by setting the TXEN output signal).

Dominant bits are sent by toggling the levels on TX0 and TX1.

This mode may be useful if the bus controllers are galvanically decoupled from the bus line by a transformer and the bit stream is not allowed to contain a DC component.


Figure 4. Bi-phase output mode.

Test Output Mode

The level connected to RXD is reflected at TX0 and TX1 with the next positive edge of the system clock (CLK_I).


Figure 5. Test output mode.

Normal Output Mode

Transmitted bit sequence (TXD) is sent via TX0 and TX1.

Clock Output Mode

For the TX0 pin, this is the same as in normal output mode. However, the data stream to TX1 is replaced by the transmit clock, whose rising edge marks the beginning of a bit period. The clock pulse width is tq.


Figure 6. Clock output mode.

Arbitration Lost Capture Register (ALC)

Address in CAN memory – 0Bh

This register is Read-only

Register value after hardware reset – 00000000

ALC.7
ALC.6
ALC.5
ALC.4
ALC.3
ALC.2
ALC.1
ALC.0
   -   
   -   
   -   
ALC

ALC.7 - ALC.5 – always in low logic state
ALC.4 - ALC.0 – 5-bit value that determines the bit-position at which arbitration lost occurred.

On arbitration lost, the corresponding arbitration lost interrupt is forced, if enabled. At the same time, the current bit position of the Bit Stream is captured into the Arbitration Lost Capture register.

The content within this register is fixed until the user's software has read out its contents once.

The capture mechanism is then activated again. The corresponding interrupt flag is cleared during the read access to the Interrupt register.

A new arbitration lost interrupt is not possible until the Arbitration Lost Capture register has been read once.

Table 7. Interpretation of arbitration lost bit number.
Arbitration Lost Capture register
(bits ALC.4 - ALC.0)
Standard Frame Format
Extended Frame Format
00000
ID.28
ID.28
00001
ID.27
ID.27
00010
ID.26
ID.26
00011
ID.25
ID.25
00100
ID.24
ID.24
00101
ID.23
ID.23
00110
ID.22
ID.22
00111
ID.21
ID.21
01000
ID.20
ID.20
01001
ID.19
ID.19
01010
ID.18
ID.18
01011
RTR
SRTR
01100
IDE
IDE
01101
-
ID.17
01110
-
ID.16
01111
-
ID.15
10000
-
ID.14
10001
-
ID.13
10010
-
ID.12
10011
-
ID.11
10100
-
ID.10
10101
-
ID.9
10110
-
ID.8
10111
-
ID.7
11000
-
ID.6
11001
-
ID.5
11010
-
ID.4
11011
-
ID.3
11100
-
ID.2
11101
-
ID.1
11110
-
ID.0
11111
-
RTR

Error Code Capture Register (ECC)

Address in CAN memory – 0Ch

This register is Read-only

Register value after hardware reset – 00000000

ECC.7
ECC.6
ECC.5
ECC.4
ECC.3
ECC.2
ECC.1
ECC.0
ECode.1
ECode.0
Dir
ECC

ECC.7 - ECC.6 – Error Code

  • 00 – bit error
  • 01 – form error
  • 10 – stuff error
  • 11 – crc error or acknowledge error

ECC.5 – Direction when error occurred

  • 0 – during reception
  • 1 – during transmission

ECC.4 - ECC.0 – 5-bit value that determines the position where the error occurred.

Table 8. Interpretation of error code.
Error Code Capture register
(bits ECC.4 - eECC.0)
Function
00000
Idle state
00001
SOF
00011
ID.28 ... ID.22
00010
ID.21 ... ID.18
00110
SRR
00111
IDE
00101
ID.17 ... ID.12
00100
ID.11 ... ID.06
01100
ID.05 ... ID.00
01110
RTR
01111
RB.1
01101
RB.0
01001
DLC
01000
CRC sequence
01010
CRC delimiter
01011
ACK slot
10011
ACK delimiter
10010
EOF
10000
Intermission
10101
Active Error Flag
10111
Passive Error Flag
10001
Overload Flag
10110
Tolerate dominant bits
10100
Error Delimiter
11000
Data Field, 8th byte
11001
Data Field, 1st byte
11010
Data Field, 2nd byte
11011
Data Field, 3rd byte
11100
Data Field, 4th byte
11101
Data Field, 5th byte
11110
Data Field, 6th byte
11111
Data Field, 7th byte

The Tolerate dominant bits position results from the superposition of error flags. If a bus error occurs, the corresponding bus error interrupt is forced, if enabled. At the same time, the current position of the Bit Stream is captured into the Error Code Capture register.

The content within this register is fixed until the user's software has read out its content once. The capture mechanism is then activated again. The corresponding interrupt flag is cleared during the read access to the Interrupt register. A new bus error interrupt is not possible until the Error Code Capture register has been read once.

Error Warning Limit Register (EWL)

Address in CAN memory – 0Dh

This register is Read-only

Register value after hardware reset – 01100000

EWL.7
EWL.6
EWL.5
EWL.4
EWL.3
EWL.2
EWL.1
EWL.0
EWL

EWL.7 - EWL.0 – 8-bit value that determines the Error Warning Limit.

When one of the Error Counters reaches the Error Warning Limit and the Error Warning Interrupt Enable bit (IER.2) is set, an Error Warning Interrupt (IR.2) will be generated.

The content of the Error Warning Limit register can only be changed in Reset mode.

A change in the error state and the corresponding Error Warning Interrupt that is generated, will not occur until Reset mode has been cancelled.

Receive Error Counter Register (REC)

Address in CAN memory – 0Eh

This register is Read-only

Register value after hardware reset or after entering Bus-Off state – 00000000

REC.7
REC.6
REC.5
REC.4
REC.3
REC.2
REC.1
REC.0
REC

REC.7 - REC.0 – 8-bit value that determines the output of the Receive Error Counter.

The maximum value of the counter is 7Fh.

The content of the Receive Error Counter can only be changed in Reset mode.

A change in the error state and the corresponding Error Warning Interrupt or Error Passive Interrupt forced by the new register content, will not occur until Reset mode has been cancelled.

Transmit Error Counter Register (TEC)

Address in CAN memory – 0Fh

This register is Read-only

Register value after hardware reset – 00000000

Register value after entering Bus-Off state – 01111111

TEC.7
TEC.6
TEC.5
TEC.4
TEC.3
TEC.2
TEC.1
TEC.0
TEC

TEC.7 - TEC.0 – 8-bit value that determines the output of the Transmit Error Counter.

If a Bus-Off event occurs, the Transmit Error Counter is initialized to 127 to count the minimum protocol-defined time (128 occurrences of the bus-free signal). Reading the counter during this time gives information about the status of the Bus-Off recovery.

The content of the Transmit Error Counter can only be changed in Reset mode.

A change in the error state and the corresponding Error Warning Interrupt or Error Passive Interrupt forced by the new register content, will not occur until Reset mode has been cancelled.

Transmit Buffer Register (TB0 – TB12)

The Transmit Buffer register allows the user to define a message for transmission. The register is thirteen bytes in length and is accessible at two address spaces:

  • Addresses 10h - 1Ch – accessible during write access in Operating (Normal) mode
  • Addresses 60h - 6Ch (Direct Addressing only) – directly readable/writeable memory placed in CAN address space.

In normal operating mode, the Transmit Buffer register (TB0-TB12, addresses 10h-1Ch) is Write-only. In Reset mode, both read and write access is possible.

Table 9 shows the content for each of the thirteen bytes in the CAN address space (in this case 10h – 1Ch). One byte (at address 10h) is used to distinguish between Standard Frame Format and Extended Frame Format configurations. In the table, address content has been further divided into two columns – the left hand column representing Standard Frame Format and the right hand column representing Extended Frame Format.

Table 9. Receive/Transmit Buffer register layout.
CAN Address
Content
10h
FRAME INFORMATION
11h
Identifier, 1st byte
Identifier, 1st byte
12h
Identifier, 2nd byte
Identifier, 2nd byte
13h
1st Data byte
Identifier 3rd byte
14h
2nd Data byte
Identifier 4th byte
15h
3rd Data byte
1st Data byte
16h
4th Data byte
2nd Data byte
17h
5th Data byte
3rd Data byte
18h
6th Data byte
4th Data byte
19h
7th Data byte
5th Data byte
1Ah
8th Data byte
6th Data byte
1Bh
not used
7th Data byte
1Ch
not used
8th Data byte

Frame Information

BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
IDE
RTR
RB.1/'0'
RB.0
DLC.3
DLC.2
DLC.1
DLC.0

IDE – Identifier Extension bit, defines message format.

  • 0 – Standard Frame Format
  • 1 – Extended Frame Format.

RTR – Remote Transmission Request bit

BIT 5:

  • for Standard Frame Format – '0'
  • for Extended Frame Format – RB.1

DLC – Data Length Code

The number of bytes in the data field of the message, calculated as:

The data length code is not considered when the RTR bit is set (logic 1).

For reasons of compatibility, the DLC code should be less than or equal to 8. It should be defined in software. Selection of a value greater than 8 will result in frame errors (the CAN Controller will try to send more than 8 data bytes, which is not compatible with the CAN2.0 specification).

Identifier, 1st byte

BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
ID.28
ID.27
ID.26
ID.25
ID.24
ID.23
ID.22
ID.21

Identifier 2nd byte for Standard Frame Format

BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
ID.20
ID.19
ID.18
RTR
-
-
-
-

Identifier, 2nd byte for Extended Frame Format

BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
ID.20
ID.19
ID.18
ID.17
ID.16
ID.15
ID.14
ID.13

Identifier, 3rd byte

BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
ID.12
ID.11
ID.10
ID.9
ID.8
ID.7
ID.6
ID.5

Identifier, 4th byte

BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
ID.4
ID.3
ID.2
ID.1
ID.0
RTR
-
-


RTR – With respect to the Transmit Buffer register, this bit is not used. The more significant 6th bit of the Frame Information byte is used. With respect to the Receive Buffer register, this bit is used and is a direct copy of the 6th bit in the Frame Information byte.

 
The identifier acts as the message's name, which is subsequently used in a receiver for acceptance filtering. It also determines the bus access priority during the arbitration process. The lower the binary value of the identifier, the higher the message priority. This is due to the larger number of leading dominant bits during arbitration.

Data byte

BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
D.7
D.6
D.5
D.4
D.3
D.2
D.1
D.0

Receive Buffer Register (RB0 – RB12)

The Receive Buffer register is thirteen bytes in length and is accessible at two address spaces:

  • Addresses 10h - 1Ch – Receive Buffer register, accessible during read access in Operating (normal) mode
  • Addresses 20h - 5Fh (Direct Addressing only) – direct read/write of entire Receive FIFO (64-bytes).

In normal operating mode, the Receive Buffer register (RB0-RB12, addresses 10h-1Ch) is Read-only. In Reset mode, both read and write access is possible.


Figure 7. Receive FIFO.

The Receive Buffer register is located as a 13-byte overlapping window within the Receive FIFO. The beginning of this window is pointed to by the Receive Buffer Start Address register (RBSA).

It is possible for there to be more than one message accessible within the Receive Buffer register, due to the fact that the register's length is 13-bytes (maximum message length) and individual messages may be shorter in length. The actual length of a message depends on the frame format – standard or extended – and the number of data bytes. Table 9 in the previous section illustrates the message format for both standard and extended frame formats.

With a 64-byte Receive FIFO, it is possible to store between 7 and 21 messages (depending on the frame format and size of the data therein).

The global layout of the Receive Buffer register is similar to that of the Transmit Buffer register.

The received Data Length Code (DLC), located in the Frame Information byte, may be greater than 8 (depending on the sender). For compatibility with the CAN2.0 specification however, the maximum number of received data bytes is limited to 8. This should be taken into account when reading a message from the Receive Buffer register.

If there is not enough space for a new message byte within the Receive FIFO, the CAN Controller generates a data overrun condition. A message that has been partially written into the Receive FIFO when the data overrun situation occurs, is deleted. This situation is indicated to the CPU via the Status register (SR.1 - Data Overrun Status) and the corresponding Data Overrun Interrupt (IR.3) that is generated, if enabled.

Acceptance Filter

The Acceptance Filter allows the user to configure the CAN Controller so that only the desired messages are written into the Receive FIFO. This is achieved by comparing the identifier bits of received messages with predefined ones stored within the Acceptance Filter registers. If there is an exact match, the message is written (accepted) into the Receive FIFO.

The Acceptance Filter is defined by the Acceptance Code registers (ACR0 – ACR3) and the Acceptance Mask registers (AMR0 – AMR3).

The identifier bit patterns of messages to be received are defined within the Acceptance Code registers.

The corresponding Acceptance Mask registers allow the definition of certain bit positions in the identifiers to be 'don't care' ('1' means don't care bit).

Two different filter modes are selectable. Mode selection is determined by bit 3 of the Mode register (MOD.3 – Acceptance Filter Mode):

  • Single filter mode (MOD.3 is logic 1)
  • Dual filter mode (MOD.3 is logic 0).

The bit correspondences between the identifier bytes of the Acceptance Filter and those of the message depend also on the currently received frame format (standard or extended).

Acceptance Code Registers (ACR0 – ACR3)

Addresses in CAN memory – 10h - 13h

These registers are accessible for read and write only in Reset mode.

Acceptance Mask Registers (AMR0 – AMR3)

Addresses in CAN memory – 14h - 17h

These registers are accessible for read and write only in Reset mode.

Register values after hardware reset – 11111111

Single filter configuration, receiving standard frame messages

The complete identifier (two bytes) including the RTR and RB.0 bits and two data bytes are used for acceptance filtering. Messages may also be accepted if there are no data bytes due to Remote Frame, or if there is none or only one data byte because of the corresponding Data Length Code. In this case, filtering of corresponding data bytes is not performed.

For successful reception of a message, all single bit comparisons have to signal acceptance.


Figure 8. Single filter configuration, receiving standard frame messages.

Single filter configuration, receiving extended frame messages

The complete identifier (four bytes), including the RTR, RB.1 and RB.0 bits, is used for acceptance filtering. For successful reception of a message, all single bit comparisons have to signal acceptance.


Figure 9. Single filter configuration, receiving extended frame messages.

Dual filter configuration, receiving standard frame messages

There are two short filters defined. A received message is compared with both filters to decide whether this message should be copied into the Receive Buffer register or not. If at least one of the filters signals an acceptance, the received message becomes valid.

The first filter compares the complete standard identifier (two bytes) including the RTR bit and the first data byte of the message. The second filter just compares the complete standard identifier including the RTR bit acceptance. In the case of Remote Frame or if no data byte exists, filtering of the corresponding data byte is not performed.


Figure 10. Dual filter configuration receiving standard frame messages.

Dual filter configuration, receiving extended frame messages

There are two short filters defined. A received message is compared with both filters to decide whether this message should be copied into the Receive Buffer register or not. If at least one of the filters signals an acceptance, the received message becomes valid.

The two defined filters are identical. Both filters compare the first two bytes of the extended identifier.


Figure 11. Dual filter configuration receiving extended frame messages.

Message Counter (MC)

The Message Counter reflects the current number of messages available within the Receive FIFO. Its value is incremented each time a new message is successfully received and accepted.

Address in CAN memory – 1Dh

This register is Read-only

Register value in Reset mode – 00000000

MC.7
MC.6
MC.5
MC.4
MC.3
MC.2
MC.1
MC.0
   -   
   -   
   -   
MC

MC.7 - MC.5 – always in low logic state.

MC.4 - MC.0 – 5-bit value defining the number of messages stored in the Receive FIFO.

Receive Buffer Start Address Register (RBSA)

Address in CAN memory – 1Eh

This register is Read-only

Register value after hardware reset – 00000000

RBSA.7
RBSA.6
RBSA.5
RBSA.4
RBSA.3
RBSA.2
RBSA.1
RBSA.0
   -   
   -   
RBSA

RBSA.7 - RBSA.6 – always in low logic state.

RBSA.5 - RBSA.0 – 6-bit value reflecting the current internal Receive FIFO address where the first byte of a received message (which is mapped to the Receive Buffer window) is stored.

The value 00h reflects address 20h of CAN address space (beginning of the Receive FIFO).

As the Receive FIFO is 64-bytes in length, the value of the RBSA register can be in the range 00h – 3Fh.

If a message exceeds address 80h it continues at 00h.

After the Release Receive Buffer command (CMR.2) is issued, the RBSA is updated to point at the start of the next received message in the Receive FIFO.

Clock Divider Register (CDR)

Address in CAN memory – 1Fh

This register is Read-only

Register value after hardware reset – 11000000

CDR.7
CDR.6
CDR.5
CDR.4
CDR.3
CDR.2
CDR.1
CDR.0
1
1
RxIntEn
Input Mode
Clock off
CD2
CD1
CD0

CDR.7 - CDR.6 – always in high logic state.

RxIntEn – activates dedicated receive interrupt pulse on TX1. When a received message has been received and written into Receive FIFO a receive interrupt pulse with the length of one bit time is generated at the TX1 pin (during the last bit of end of frame). The output should operate in normal output mode.

InputMode – when 1, activates CAN input test mode. In this mode, Receiver input is connected internally with Transmitter output. This mode allows you to perform CAN Controller tests without connecting it to the CAN-bus.

Clock off – setting this bit deactivates the CLK_OUT pin. If this bit is set, the CLK_OUT output pin is kept in the low logic state during Sleep mode, otherwise it is in the high logic state.

CD2 - CD0 – defines clock divider for generation of CLK_OUT signal from the system CLK_I signal.