Net Parameters with no Value

Old Content - visit altium.com/documentation

This compiler hint appears when a parameter set object is attached to a net object (wire or bus) and at least one of the defined parameters in the set has no value assigned to it. The message is displayed in the Messages panel in the following format:

Invalid net-parameter value at Location,

where

Location is the X,Y coordinates for the hotspot of the parameter set object associated to the net.

Default Report Mode

Warning

Recommendation

Access the Parameters dialog for the offending parameter set object and ensure that all parameters defined within have a value assigned to them. If the offending constituent parameter is not required, simply remove it from the set.