Overshoot - Falling Edge

Old Content - visit altium.com/documentation

Rule categorySignal Integrity

Rule classification: Unary

Summary

Specifies the maximum allowable overshoot (ringing below the base value) on the falling edge of the signal.

Constraints

Default constraints for the Overshoot - Falling Edge rule.

  • Maximum (Volts) - the value for the maximum permissible overshoot on the falling edge of the signal. (Default = 1.000).

How Duplicate Rule Contentions are Resolved

All rules are resolved by the priority setting. The system goes through the rules from highest to lowest priority and picks the first one whose scope expression(s) match the object(s) being checked.

Rule Application

Batch DRC and during Signal Integrity analysis.