Release notes for Altium Designer 10 update (10.537.22385)
Additional Resources
Updated plug-ins from release 10.516.22330 to 10.537.22385
Date: 13 May 2011
Note: Installation of the below modules will bring their revision up to 10.537.22385. Note: The Platform Build number remains at 10.516.22330 for this release, as the Altium Designer Base module is not updated.
System Components: PCB System
3648 | Import of board outline boundaries containing arcs and multi-line component Description text has been corrected. |
4397 | PCB will not longer cause AD to run Out of Memory when changing one or more properties of component designator/comment using the PCB Inspector for large boards with components containing 3D bodies. |
4467 | The Long delay / GUI lock-ups after long PCB operations requiring a lot of Undo compressions no longer happens. |
4595 | "Duplicate Rule" menu item has been added to the right click menu in the "PCB Rules and Constraints Editor". Duplicate rule is given the next priority down from the rule being duplicated. View BugCrunch report. |
4649 | DRC Clearance Violations now show the actual distance compared to the rule distance in the text summary. View BugCrunch report. |
4725 | Coordinate "Text Height" property can now be edited when using the PCB Inspector / List panels. View BugCrunch report. |
4759 | A typo was fixed in the Confirm dialog shown when defining a board shape from a STEP model and a non-planar face was selected. |
4838 | A crash on closing a PCB document if copper pours are modified & then removed from the design will no longer occur. |
System Components: Schematic System
4592 | A four-way junction formed in a schematic will no longer be replaced by a cross over by the optimizer. View BugCrunch report. |
4870 | Four-way junctions are no longer optimized out of schematics. View BugCrunch report. |
System Components: Data Management
3999 | An error no longer occurs when pasting from an Excel spreadsheet back into the Component Definitions region of a Component Library file. |
4050 | The Download command on the right-click menu for a vault component has been removed. |
4250 | The detailed Item view for a vault-based Item will now always be brought into focus when using the "Full Item Details" command. |
4251 | You can now view the lifecycle diagram for items in the vaults panel and also establish new revisions from there. |
4278 | It is now possible to change the case of a parameter name in the Component Library Document. |
4347 | PCB Component and SCH Symbol cannot be placed from the vaults panel. Placement is done with Components. The menu commands are now hidden to avoid confusion. |
4847 | Download component will create a folder with release documents for both symbol and footprint now. |
4895 | When connecting to a vault, using alternative credentials are now unchecked by default. |
System Components: Altium Designer Localization
4766 | Japanese localization of Altium Designer updated. |
4832 | Korean localization of Altium Designer updated. |
4833 | Simplified Chinese localization of Altium Designer updated. |